$140.26
List: $161.52 |Save: $21.26

PGI BarriAire Gold Particulate Hood Extended Bib with Nomex Nano Flex Face Opening

SKU: 3979471-7//IN STOCK, ORDER NOW!

Details

PGI BarriAire Gold Particulate Hood Comprehensive Coverage

Extended Bib with Nomex® Nano Flex Face Opening
Particulate coverage throughout entire head including Sure‑Fit™ panel at crown. Front and back bib extends particulate barrier coverage beyond critical areas as identified by NFPA – Maximum Protection. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition. Certification to the NFPA 1971, 2018 Edition Option for Particulate Protection – Current Edition.

Fabric Description:
Quilted composite durable water resistant finish on exterior layer of jersey knit with Nomex® Nano Flex particulate barrier between the inside layer of jersey knit. Averages 95%‑98% particulate filtration efficiency that actually improves with repeated launderings.
 
Fabric Performance ValuesRequirements for NFPA
1971 - 2018 Edition
PGI Test Results
Particulate Efficiency≥ 90%96%
Thermal Protective Performance (TPP)  
     Rib Knit  
  • As Recieved
  • After 5 Washings
20.0 (min)
20.0 (min)
30.2
33.1
     Quilted Composite  
  • As Recieved
  • After 5 Washings
20.0 (min)
20.0 (min)
29.3
30.8
Total Heal Loss (THL)≥ 325 W/m2401.3 W/m2
Hood Material Burst Strength> 225 N614 N
Flame Resistance Test
Quilted Composite
  
     After Flame (Wales x Courses)  
  • As Recieved
  • After 5 Washings
≤ 2.0 sec
≤ 2.0 sec
0.0 sec x 1.0 sec
1.0 sec x 1.0 sec
     Char Length (Wales x Courses)  
  • As Recieved
  • After 5 Washings
≤ 100 mm
≤ 100 mm
18 mm x 17 mm
3 mm x 2 mm
Cleaning Shrinkage Resistance Test  
Hood Measurement  
  • After 5 Washings
 -5%-0.3%
Face Opening Measurement  
  • After 5 Washings
Meets RequirementYES
Heat & Thermal Shrinkage Resistance Test  
     Hood Measurement  
  • As Recieved
  • After 5 Washings
≥ -10%
≥ -10%
0%
0%
     Face Opening Measurement  
  • As Recieved
  • After 5 Washings
Meets Requirement
Meets Requirement
YES
YES
Seam Breaking Strength Test  
  • Quilted to Quilted
> 181 N1064 N
Melt or Drop When Exposed to FlameNo Melting or DrippingNONE

Ratings & Reviews

No reviews available

Be the first to Write a Review